Electrical Machines: AC Generators Problem SolvingA three-phase turbo alternator has a reactance of 15 ohms and negligible resistance, the machine draws an armature current of 250 amperes at 0.8 pf lagging when running on 12,000 volts infinite bus-bars. If the steam admission is constant but the emf is raised by 20%, calculate the new operating pf.
A. 0.547
B. 0.586
C. 0.509
D. 0.575
Problem Answer:
The new operating pf a three-phase turbo alternator is equal to 0.575.
This content is for Premium Member. Tired of ads?
Subscribe To Unlock The Content! and Remove Ads.
- Solution: A field current of 50 A produces a full-load armature current of 200 A
- Solution: The voltage regulation of an alternator having 0.75 leading
- Solution: The harmonic which would be totally eliminated from the alternator
- Solution: The winding of a 4-pole alternator having 36 slots and a coil span of 1 to 8
- Solution: A 50-Hz alternator will run at the greatest possible speed
- Solution: The frequency of voltage generated by an alternator having 4-poles
- Solution: Determine the power factor of alternator B
- Solution: Find the frequency in kilocyles per second in the armature of a 10 pole
- Solution: What are the resulting loads of the alternators
- Solution: Solve for the power factor of alternator B
- Solution: Determine the system reactive power
- Solution: Calculate the new operating pf
- Solution: What would be the savings in watts if the power factor were raised to 80%?
- Solution: Determine the power factor at the maximum output
- Solution: What is the DC resistance per phase?
- Solution: What is the effective resistance per phase?
- Solution: What will be the terminal voltage for the same excitation and load current
- Solution: Determine the open circuit emf of the alternator
- Solution: Determine the nominal impedance per phase of a three-phase alternator
- Solution: Determine the per phase nominal impedance of alternator
- Solution: What is the pitch factor?
- Solution: What is the speed of a 100 kW, 230-volt, three-phase, four-pole, 60 Hz alternator?
More Questions in: AC Generators Problem
Online Question and Answer in AC Generators Series | REE Board Exam
P inoyBIX educates thousands of reviewers and students a day in preparation for their board examinations. Also provides professionals with materials for their lectures and practice exams. Help me go forward with the same spirit.
“Will you subscribe today via YOUTUBE?”
TIRED OF ADS?
- Become Premium Member and experienced complete ads-free content browsing.
- Full Content Access to Premium Solutions Exclusive for Premium members
- Access to PINOYBIX FREEBIES folder
- Download Reviewers and Learning Materials Free
- Download Content: You can see download/print button at the bottom of each post.
PINOYBIX FREEBIES FOR PREMIUM MEMBERSHIP:
- CIVIL ENGINEERING REVIEWER
- CIVIL SERVICE EXAM REVIEWER
- CRIMINOLOGY REVIEWER
- ELECTRONICS ENGINEERING REVIEWER (ECE/ECT)
- ELECTRICAL ENGINEERING & RME REVIEWER
- FIRE OFFICER EXAMINATION REVIEWER
- LET REVIEWER
- MASTER PLUMBER REVIEWER
- MECHANICAL ENGINEERING REVIEWER
- NAPOLCOM REVIEWER
- Additional upload reviewers and learning materials are also FREE
FOR A LIMITED TIME
If you subscribe for PREMIUM today!
You will receive an additional 1 month of Premium Membership FREE.
For Bronze Membership an additional 2 months of Premium Membership FREE.
For Silver Membership an additional 3 months of Premium Membership FREE.
For Gold Membership an additional 5 months of Premium Membership FREE.
Join the PinoyBIX community.