This is the Multiple Choice Questions Part 7 of the Series in Philippine Electrical Code (PEC) as one of the Electrical Engineering topic. In Preparation for the REE Board Exam make sure to expose yourself and familiarize in each and every questions compiled here taken from various sources including but not limited to past Board Exam Questions in Electrical Engineering field, Electrical Engineering Books, Journals and other Electrical Engineering References.
Continue Practice Exam Test Questions Part 7 of the Series
Choose the letter of the best answer in each questions.
⇐ MCQ in Philippine Electrical Code (PEC) Part 6 | REE Board Exam
301. RME Board April 1996
Give the minimum vertical clearance from finished grade of a service drop conductor installed between buildings on the residential properties and driveways?
A. 5,500 mm
B. 4,600 mm
C. 3,700 mm
D. 3,100 mm
Answer: Option B
Solution:
302. Where the neutral is NOT available, the grounding impedance shall be installed between the _____.
A. grounding electrode and any of the current carrying conductor
B. grounding electrode and any neutral derived from grounding transformer
C. grounding electrode and the system neutral of other station
D. all of these
Answer: Option B
Solution:
303. The voltage developed between the portable or mobile equipment frame and ground by the flow of maximum ground fault current shall NOT exceed ____.
A. 100 V
B. 50 V
C. 150 V
D. 30 V
Answer: Option A
Solution:
304. A single electrode consisting of a rod, pipe or plate shall have resistance to ground of _____ or less.
A. 20 ohms
B. 15 ohms
C. 25 ohms
D. 30 ohms
Answer: Option C
Solution:
305. Where more than one electrode is used, each electrode of one grounding system shall NOT be less than _____ from any other electrodes of another grounding system.
A. 1,800 mm
B. 2,000 mm
C. 2,400 mm
D. 1,900 mm
Answer: Option D
Solution:
306. RME Board April 1995
Who shall make the final decision in the implementation of controversial provisions of the Philippine Electrical code?
A. IIEE Board of Governors
B. Board of Electrical Engineering
C. Building Official
D. IIEE Code Committee
Answer: Option B
Solution:
307. For equipment protected by a 20-A over current device, the minimum size of the equipment grounding conductor using copper shall be _____.
A. 2.0 mm²
B. 3.5 mm²
C. 1.25 mm2
D. 5.5 mm²
Answer: Option B
Solution:
308. The height of the air terminals shall be such as to bring the tip not less than ____ above the object to be protected for 6,000-mm maximum intervals.
A. 250 mm
B. 254 mm
C. 300 mm
D. 150 mm
Answer: Option B
Solution:
309. The minimum clearance between the overhead ground wires and the highest protection on the protected structure shall be _____.
A. 1,600 mm
B. 1,500 mm
C. 1,800 mm
D. 1,700 mm
Answer: Option C
Solution:
310. REE Board April 1994, RME Board April 1995
S2 means
A. duplex switch
B. two-pole switch
C. 2-way switch
D. two-throw switch
Answer: Option A
Solution:
311. Which of the following conductors is applicable only on dry locations?
A. type THW
B. type THWN
C. type RH
D. None of these
Answer: Option C
Solution:
312. Enclosures for over current devices shall be mounted in _____ position.
A. horizontal
B. vertical
C. diagonal
D. any of these
Answer: Option B
Solution:
313. RME Board October 1995
What is the minimum depth of clear working space in front of a switchboard rated at 4,160 volts, where there are exposed energized parts on both sides of the workspace?
A. 1,000 mm
B. 1,900 mm
C. 1,600 mm
D. 2,000 mm
Answer: Option B
Solution:
314. A 2.0mm² TW copper conductors has an ampacity equal to______.
A. 20 A
B. 10 A
C. 15 A
D. 25 A
Answer: Option C
Solution:
315. Circuits with voltage of 600 V or less in a rigid non-metallic conduit approved for direct burial without concrete encasement and placed in trench below a 50 mm thick concrete or equivalent shall have a minimum cover distance of _____.
A. 300 mm
B. 400 mm
C. 460 mm
D. 200 mm
Answer: Option A
Solution:
316. A single enclosed raceway for conductors or cables.
A. Box
B. Duct
C. Cabinet
D. Gutter
Answer: Option B
Solution:
317. Which of the following statement is NOT correct?
A. The use of inductive ballast for fluorescent lamps is usually because it is the most efficient.
B. Lighting fixtures having exposed ballast shall be so installed that they will not be in contact with combustible materials.
C. Ballast which incorporates an auto-transformer to raise the voltage to more than 300 V shall be supplied only by a supply system which is grounded.
D. A receptacle outlet installed outdoors shall be located so that water accumulation is not likely to touch the outlet cover or plate.
Answer: Option A
Solution:
318. Conductor crossings of more than ____ type FCC cable runs shall not be permitted.
A. two
B. three
C. four
D. five
Answer: Option A
Solution:
319. A generator set used for standby power systems shall have a time delay feature permitting a ____ minute setting to avoid retransfer in case of short time reestablishment of the normal source.
A. 10
B. 8
C. 12
D. 15
Answer: Option D
Solution:
320. Rigid metal conduit shall be firmly fastened within ____ of each outlet box.
A. 800 mm
B. 900 mm
C. 760 mm
D. 600 mm
Answer: Option B
Solution:
321. Type TW conductors have a minimum operating temperature of _____.
A. 75°C
B. 50°C
C. 60°C
D. 90°C
Answer: Option C
Solution:
322. Type UF cable shall be permitted for use ______.
A. underground including direct burial to earth
B. underground but concealed with a rigid metal conduit
C. underground but not direct burial to earth
D. none of these
Answer: Option A
Solution:
323. Enclosures of metal foe electrodes of electric discharge tubing’s shall NOT be less than ______ thick sheet metal.
A. 0.40 mm
B. 0.35 mm
C. 0.45 mm
D. 0.50 mm
Answer: Option D
Solution:
324. A general-purpose single-phase motor rated 0.5 hp has a current rating of 5 A. What should be the setting of the overload relay that is installed to protect the motor? Assume the service factor of the motor to be 1.0.
A. 5.75 A
B. 5.5 A
C. 5.0 A
D. 6.25 A
Answer: Option A
Solution:
325. The grounded conductor of type FC (flat conductor) cable shall be identified by means of a distinctive and durable white or ____ marking.
A. green
B. natural gray
C. brown
D. yellow stripe
Answer: Option B
Solution:
326. For multiple motors on a single crane or hoist, the minimum circuit ampacity of the power conductor shall be the nameplate full load ampere raring of the largest motor for any single crane motion, plus ____ percent of the nameplate full load ampere rating of the next largest motor.
A. 25%
B. 30%
C. 40%
D. 50%
Answer: Option D
Solution:
327. Individuality covered or insulated grounding conductors shall have a continuous outer finish that is either green, or green with one more ______ stripes.
A. white
B. gray
C. yellow
D. violet
Answer: Option C
Solution:
328. Intermediate metal conduit shall be shipped in standard lengths of ______.
A. 5,000 mm
B. 4,000 mm
C. 2,000 mm
D. 3,000 mm
Answer: Option D
Solution:
329. The smallest copper conductor of type MC cable shall be ______.
A. 2.0 mm²
B. 1.25 mm²
C. 0.75 mm2
D. 3.5 mm²
Answer: Option C
Solution:
330. If a bare live conductor is touched accidentally, the severity of the electric shock is determined primarily by
A. the size of the conductor
B. the type of the power supply, whether AC or DC
C. the contact resistance between the bare wire and the person at the point of contact
D. the current flowing in the conductor
Answer: Option C
Solution:
331. Smallest electrical trade size for flexible metal conduit.
A. 15 mm
B. 20 mm
C. 25 mm
D. 10 mm
Answer: Option A
Solution:
332. As applied to circuit breaker, a term indicating there is purposely introduced a delay in the tripping action of the CB.
A. Delay-on
B. Adjustable trip
C. Inverse time
D. Delay-off
Answer: Option C
Solution:
333. A factory assembly of one or more conductors each individually insulated and enclosed in a loose fit nonmetallic flexible conduit as an integrated gas spacer.
A. type MC
B. type NMC
C. type FCC
D. type IGS
Answer: Option D
Solution:
334. Hazardous locations are classified by the Philippine Electrical Code in how many classes?
A. Two classes
B. Four classes
C. Three classes
D. One class
Answer: Option C
Solution:
335. The branch of circuit conductors supplying one or more units of data processing system shall have an ampacity NOT less than ____ of the total connected load.
A. 110%
B. 125%
C. 100%
D. 115%
Answer: Option B
Solution:
336. The main disconnecting means for all electric driven irrigation machines shall be visible and NOT more than ____ from the machine.
A. 10 m
B. 15 m
C. 12 m
D. 8 m
Answer: Option B
Solution:
337. A factory assembly of two or more insulated conductors having an outer sheath of moisture resistant flame-retardant, non-metallic material.
A. Non-metallic sheathed cable
B. Mineral insulated cable
C. Armored cable
D. Medium voltage cable
Answer: Option A
Solution:
338. The bottom of sign and outline lighting enclosures shall NOT be less than _____ above areas accessible to vehicles.
A. 5,000 m
B. 4,800 m
C. 4,700 m
D. 4,900 m
Answer: Option D
Solution:
339. Which is the most important thing to do when a person has been shocked by electricity?
A. Separate the victim from the electric wire as soon as possible making sure that you do not become another victim
B. Call for competent help
C. Apply resuscitation
D. Disconnect the switch
Answer: Option A
Solution:
340. As applied to lighting protection, an attachment to secure the conductor to the structure or building.
A. Bonder
B. Stapler
C. Support
D. Fastener
Answer: Option D
Solution:
341. In a watercraft, when the source of electric power is a generator, it shall be automatically started and connected to the emergency switchboard within ____ seconds of loss of the main source of electrical power.
A. 40
B. 50
C. 25
D. 45
Answer: Option D
Solution:
342. Generator neutral maybe connected in common, provided that the third harmonic content of the waveform of each generator does NOT exceed _____.
A. 3%
B. 4%
C. 5%
D. 6%
Answer: Option C
Solution:
343. As a general rule, equipment rated 1,000A or more and measuring more than 1,900 mm wide, containing over current devices, shall have an entrance at both ends of the switchboard room. The width and height of each entrance shall be NOT less than the following dimensions. Which one is correct?
A. 800 mm wide x 2,000 mm high
B. 600 mm wide x 2,000 mm high
C. 600 mm wide x 2,200 mm high
D. 800 mm wide x 2,200 mm high
Answer: Option B
Solution:
344. Type AC cable shall be secured by approved staples, straps hangers or similar fittings within _____ from every outlet box, junction box, cabinet or fitting.
A. 200 mm
B. 150 mm
C. 400 mm
D. 300 mm
Answer: Option D
Solution:
345. RME Board April 1995
Maximum electric trade size of liquid tight flexible metal conduit.
A. 125 mm
B. 150 mm
C. 100 mm
D. 200 mm
Answer: Option C
Solution:
346. Communication conductors shall be separated at least _____ from conductors of any electric light or power circuits.
A. 50 mm
B. 40 mm
C. 60 mm
D. 75 mm
Answer: Option A
Solution:
347. Receptacles used in circuits operating at less than 50 V shall have an ampere rating of not less than _____.
A. 20 A
B. 10 A
C. 15 A
D. 5 A
Answer: Option C
Solution:
348. Each resistance welder shall have an over current device rated set not more than ______ percent of the conductor rating.
A. 300
B. 250
C. 175
D. 150
Answer: Option A
Solution:
349. To support conduit on a hollow block wall, use one of the following methods. Which one is this?
A. Machine screw
B. Lag screw
C. Toggle bolt
D. Through bolt
Answer: Option C
Solution:
350. Circuit containing electric discharge lighting transformers exclusively shall NOT be rated in excess of ______.
A. 20 A
B. 30 A
C. 15 A
D. 40 A
Answer: Option B
Solution:
⇒ MCQ in Philippine Electrical Code (PEC) Part 8 | REE Board Exam
Questions and Answers in Philippine Electrical Code
Following is the list of practice exam test questions in this brand new series:
P inoyBIX educates thousands of reviewers and students a day in preparation for their board examinations. Also provides professionals with materials for their lectures and practice exams. Help me go forward with the same spirit.
“Will you subscribe today via YOUTUBE?”
TIRED OF ADS?
- Become Premium Member and experienced complete ads-free content browsing.
- Full Content Access to Premium Solutions Exclusive for Premium members
- Access to PINOYBIX FREEBIES folder
- Download Reviewers and Learning Materials Free
- Download Content: You can see download/print button at the bottom of each post.
PINOYBIX FREEBIES FOR PREMIUM MEMBERSHIP:
- CIVIL ENGINEERING REVIEWER
- CIVIL SERVICE EXAM REVIEWER
- CRIMINOLOGY REVIEWER
- ELECTRONICS ENGINEERING REVIEWER (ECE/ECT)
- ELECTRICAL ENGINEERING & RME REVIEWER
- FIRE OFFICER EXAMINATION REVIEWER
- LET REVIEWER
- MASTER PLUMBER REVIEWER
- MECHANICAL ENGINEERING REVIEWER
- NAPOLCOM REVIEWER
- Additional upload reviewers and learning materials are also FREE
FOR A LIMITED TIME
If you subscribe for PREMIUM today!
You will receive an additional 1 month of Premium Membership FREE.
For Bronze Membership an additional 2 months of Premium Membership FREE.
For Silver Membership an additional 3 months of Premium Membership FREE.
For Gold Membership an additional 5 months of Premium Membership FREE.
Join the PinoyBIX community.